>American Split-phase hybrid inverter

Please fill in the email and download the information immediately

The split-phase hybrid inverter automatically matches mainstream batteries, is UL certified, integrates a breaker, supports two independent battery strings, and features a 200A pass-through with 100% unbalanced load capability.

American Split-phase hybrid inverter (battery high voltage)
American Split-phase hybrid inverter (battery high voltage)
American Split-phase hybrid inverter (battery high voltage)
American Split-phase hybrid inverter (battery high voltage)
Product Highlights
High-Voltage Efficiency & Up to 36kW PV Input
Powered by a wide 120–400V high-voltage battery architecture with 4 MPPTs (up to 36kW PV input), achieving a peak 96.7% CEC efficiency.
200A Pass-Through & Whole-Home Backup Power
Delivers heavy-duty backup from 15.3kW to 24kW with a 200A grid pass-through capability and 100% unbalanced load support.
Built-in Breaker, AFCI Protection & Type 3R Ruggedness
Features an integrated circuit breaker, advanced Arc Fault Protection (AFCI), and an IP65/Type 3R weather-proof enclosure with remote upgrade support.
Choose our benefits

Reduce electricity costs by 50% per year

Free energy available at night

Participate in peak load shifting to gain additional economic benefit

keeping critical load operation in power of

Support 7*24 remote service

ModelR16KH2NAR18KH2NAR20KH2NAR22KH2NAR24KH2NA
PV input data
Max. PV input power (kW)2427303336
Max. PV input voltage (V)500
Min. PV input voltage (V)120
Start-up voltage (V)120
MPPT voltage range (V)120~500
MPPT voltage range@full-load (V)150~430
Rated PV input voltage (V)310
No. of MPPT trackers4
No. of strings per MPPT tracker2/2/2/2
Max. input current per MPPT (A)32/32/32/32
Max. short-circuit current per MPPT (A)44/44/44/44

Battery input data
Battery typeLithium-ion / Lead-acid
Max. charge / discharge power (kW)1618202224
Battery voltage range (V)120~400
Battery voltage range@full-load (V)160-400180-400200-400220-400240-400
Max. charging / discharging current (A)50+50 / 50+50
Rated charge / discharge current (A)50+50 / 50+50
Power factor0.8 leading - 0.8 lagging
Battery charging strategySelf-adaption to BMS
BMS communication CAN

AC output data (grid side)
Rated output power (kW)1618202224
Max. apparent output power (kVA)1618202224
Max. apparent input power(kVA)1618202224
Rated grid voltage (V)120/240
Grid voltage range (V)211~264
Grid input voltage (V)240
Rated grid frequency (Hz)60
Grid frequency range(Hz)58.8~61.2
Rated output current (A)66.67583.391.6100
Max. AC output current (A)66.67583.391.6100
Max. apparent input current (A)66.67583.391.6100
Max. grid passthrough current(A)200
Grid typeL1/L2+N+PE

AC output data (load side)
Rated output power (kW)1618202224
Max. apparent output power (kVA)1618202224
Max. apparent input power(kVA)1618202224
Rated output voltage (V)120 / 240
Rated output frequency (Hz)60
Rated output current (A)66.67583.391.6100
Max. AC output current (A)200
Back-up switch time (ms)<20

Protection
Supported protection

PV reverse polarity protection, Anti-islanding protection, Ground fault protection, Battery reverse protection,

Leakage current protection, Insulation resistance detection, Backup output short circuit protection,

Arc fault protection, AC output over-current protection

Surge protectionDC Type II / AC Type II
Over voltage categoryDC Type II / AC Type III

General data
Ingress protectionIP65
Operating temperature range (℃)-25~+60
CoolingFAN cooling
Relative humidity0-85%
Operating altitude (m)/
Dimensions W*D*H (mm)/
Weight (kg)/
Topology (solar / battery)Transformerless / Transformerless
Noise emission (dB)/

Display and communication
DisplayTouch panel
CommunicationRS485,CAN,WIFI,4G