The H1 Series High-Voltage hybrid inverter consists of an inverter and transformer designed for the American market. This split-phase inverter meets the battery voltage range of 85~400V and covers a power range of 6-12kW. Accordingly, it’s compatible with a wide range of mainstream batteries and is suitable for large-capacity home energy storage systems in North America.
Reduce electricity costs by 50% per year
Free energy available at night
Participate in peak load shifting to gain additional economic benefit
keeping critical load operation in power of
Support 7*24 remote service
| Technical specification | R6KH1NA | R8KH1NA | R10KH1NA | R12KH1NA |
| Input (PV) | ||||
| Max. power(kW) | 7.8 | 10.4 | 13 | 15.6 |
| Max. DC voltage(V) | 500 | |||
| MPPT voltage range(V) | 125~500 | |||
| Max.Input current of single MPPT(A) | 12 | |||
| MPPT tracker/strings | 4/1 | |||
| AC output | ||||
| Rated output power(kVA) | 6 | 8 | 10 | 12 |
| Max. apparent Power (kVA) | 6.6 | 8.8 | 11 | 12 |
| Max. output current(A) | 27.5 | 36.7 | 45.8 | 50 |
| Grid voltage/range(V) | 240/211~264 | |||
| Frequency (Hz) | 50 /60 | |||
| PF | 0.8lagging-0.8leading | |||
| THDi | <3% | |||
| AC output topology | Split phase、single phase | |||
| Battery | ||||
| Battery voltage range(V) | 85~400 | |||
| Max. charging voltage(V) | 400 | |||
| Full battery voltage(V) | 85 | 110 | 140 | 160 |
| Max. charge/discharge current(A) | 80/80 | |||
| Battery type | Lithium /Lead-acid | |||
| Communication interface | CAN,RS485 | |||
| EPS output | ||||
| Rated power (kVA) | 6 | 8 | 10 | 12 |
| Rated output voltage(V) | 220-240 /110-120 | |||
| Rated frequency(Hz) | 50/60 | |||
| Automatic switching time (ms) | <20 | |||
| THDu | <2% | |||
| Overload capacity | 110%,30S/120%,10S/150%,0.02S | |||
| General data | ||||
| DC Max. efficiency | ≥98.2% | |||
| CEC efficiency | ≥97.2% | |||
| Ingress protection | IP65/NEMA 3R | |||
| Noise emission(dB) | <25 | <25 | <29 | <29 |
| Operation temperature(℃) | -25~60 | |||
| Cooling | Natural | |||
| Relative humidity | 0 ~95%(non-condensing) | |||
| Operation altitude (m) | 2,000 (>2,000 Derating) | |||
| Weight(kg) | 34 | |||
| Dimensions W * D * H (mm) | 560* 220* 680 | |||
| Self-consumption(W) | <20 | |||
| Display and communication | ||||
| Display | LCD | |||
| Interface:RS485/Wifi/4G/CAN | Yes/ Opt/ Opt/ Yes | |||
| Safety standard | UL1741SA all options, UL1699B, CSA 22.2 | |||
| EMC | FCC Part 15, Class B | |||
| On-grid | IEEE 1547, Rule 21, Cpuc Rule 21, SRD V2.0 UL1741SA, UL1741SB | |||