>MPS Hybrid inverter

Please fill in the email and download the information immediately

Megarevo MPS hybrid inverters feature an integrated design that combines PV controllers, energy storage converters, and on/off-grid automatic switching units, greatly improving customer deployment efficiency and reducing installation costs. The hybrid inverter can flexibly configure PV capacity, greatly improving microgrid system availability and making it suitable for remote areas and islands with relatively weak power. Our MPS series covers both on grid inverter and off grid inverter.


MPS hybrid inverter
MPS hybrid inverter
MPS hybrid inverter
MPS hybrid inverter
MPS hybrid inverter
MPS hybrid inverter
MPS hybrid inverter
MPS hybrid inverter
Product Highlights
Safe and reliable
Our hybrid inverters are tested and certified to meet major international on-grid and safety standards, including EN 62109-1/-2, EN 62477-1, EN 61000-6-2/-6-4, IEC61727, IEC62116, IEC61683 NRS 097-2-1:2017, ASGC, AS/NZS 4417.1, CEI 0-21, CEI 0-16, G99 EN 50549-1, VDE 4105 test certification.
Flexible configuration
MPS hybrid inverters supports PV, diesel generator, battery and load at the same time, with strong system adaptability and black start capability. Multiple working modes can be flexibly configured to meet diverse application requirements.
Convenient operation and maintenance
Designed as a hybrid power inverter for long-term operation, it supports unattended operation with an HMI digital display panel, allowing operators to quickly judge the operating status and health of the equipment, while cloud-based EMS integration enables remote monitoring and management.
Choose our benefits

Save more installation, commissioning costs

Reduce the use of fossil fuels and be more environmentally friendly

Increase the penetration of renewable energy

Continuous and stable power supply

PV expansion will be more convenient in the future

MPS hybrid inverter
ModelMPS0030MPS0050  MPS0100MPS0150MPS0250MPS0500
AC(on-grid)
Max. output power (kW)3355110165275550
Rated output power (kW)3050100150250500
Rated voltage (V)400
Voltage range (V)320~460
Rated current (A)43
72144216361722
Rated frequency (Hz)50/60
Frequency range (Hz)45~55 / 55~65
THDi<3%
Power factor1leading-1lagging(settable)
Grid type3W+N+PE

AC(off-grid)
Max. output power (kW)3355110165275550
Rated power (kW)3050
100150250500
Rated voltage (V)400
Rated current (A)4372
144216361722
THDu≤1% linear;  or≤5% nonlinear
Rated frequency (Hz)50/60
Overload capacity110% long-term, 120% 1min

PV input
Max. PV input voltage (V)1,000
Max. PV power (kW)82.582.5165/247.5165/247.5/330330/412.5660/742.5/825
MPPT module quantity112/32/3/44/58/9/10
MPPT voltage range (V)250~1000

Battery
Battery voltage range (V) 250~850320~850420~950420~950420~950500~950
Max. charging power (kW)3355110165275550

General data
Dimension W*D*H (mm)800*800*1,900800*800*1,9001,200*800*2,0501,200*800*2,050(600*720*2,050)*1+1,200*800*2,050(600*720*2,050)*2+1,600*1,050*2,050
Weight (kg)6207201,120/1,1501,250/1,280/1,3101,950/1,9803,205/3,235/3,265
Operation temperature (℃) -30 ~ 55
Relative humidity0 ~95% non-condensing
Ingress protectionIP20
Noise emission (dB)<70
Operating altitude (m)>3,000 Derating
CoolingAir Cooling

Display and communication
DisplayLCD touch-screen 
BMS communicationRS485, CAN
EMS communication RS485, TCP/IP
Certificates

EN 62109-1/-2, EN 62477-1, EN 61000-6-2/-6-4, NRS 097-2-1:2024, ASGC


MPS - G3 hybrid inverter
ModelMPS0100-G3MPS0150-G3
AC(on-grid)
Max output power (kVA)110165
Rate output power (kW)100150
Rated voltage(V)400
Voltage range (V)320~460
Rated current (A)144216
Rated frequency (Hz)50/60
Frequency range (Hz)45~55 / 55~65
THDi<3%
Power factor1lagging-1leading(Settable)
AC connection3W+N+PE
Transformer ratio270/400270/400

AC(off-grid)
Max output power (kVA)110165
Rated power (kW)100150
Rated voltage (V)400
Rated current (A)144216
THDu≤1% linear;  or≤5% nonlinear
Rated frequency (Hz)50/60
Overload capacity110% long-term, 120% 1min

PV input
Max.PV input voltage (V)1,000
Max.PV power (kW)120/180/240
MPPT module quantity2/3/4
MPPT voltage range (V)250-850
MPPT voltage range@full load (V)450-850

Battery
Battery voltage range (V) 420~850
Max. charging power (kW)110165

General data
Dimension W*D*H (mm)800*800*1,950800*800*1,950
Net weight (kg)970/1,000/1,0301,100/1,130/1,160
Operation temperature (℃) -30 ~ 55
Relative humidity0 ~95% non-condensing
Ingress protectionIP20
Noise emission (dB)<70
Operating altitude<5000m(>3,000 Derating)
CoolingAir Cooling

Display and communication
DisplayLCD touch-screen 
BMS communicationRS485, CAN
EMS communication RS485, TCP/IP
Certificates

EN62109-1/-2, EN62477-1, EN61000-6-2, EN61000-6-4, South Africa NRS097-2-1:2017, 

Pakistan & India IEC61727, IEC62116, IEC 61683


MPS - M hybrid inverter
ModelMPS-M0125MPS-M0250
PV data
Max. PV input voltage (Vdc)1000
PV startup voltage (V)250
MPPT rated power (kW)225450
MPPT full load voltage range (Vdc)550~950
MPPT quantity36
Max. power per MPPT (kW)82.5
Max. current per MPPT (A)135

DC data

Rated DC power (kW)125250
DC operating voltage range (Vdc)650~950(3W+N+PE)
Max. continuous DC current (A)±230±460



AC grid-side data

Rated AC power (kW)250500
Rated voltage (Vac)L-N:220/230/240/277; L-L:380/400/415/480
Rated AC current (A)360722
THDi<3%(of rated power)
Rated voltage/voltage range (Vac)400Vac±15%(According to local standards)
Rated frequency/frequency range (Hz)50±5/60±5(According to local standards)
ower factor/regulation range>0.99; -1~ +1

AC load side data
Rated AC power (kW)125250
Rated voltage (Vac)L-N:220/230/240/277; L-L:380/400/415/480
Rated frequency (Hz)50/60
THDu<3%(of linear load)
Load unbalance100% Three-phase unbalanced
Overload capacity110%:continuous; 110%~120%:2min; >120%:200ms

Communication
Human-computer interaction7" Touch screen / Local web / Upper computer (Optional)
Communication interfaceEthernet / RS485/CAN
Communication with BMSRS485 / CAN(Optional)
Communication with EMSRS485 / Ethernet(Optional)

Protect
AC/DC surge protectionType II
Battery/PV short circuit protectionCurrent control+fuse+DC contactor+breaker
Load/grid short circuit protectionCurrent control+fuse+AC relay+breaker
RCD/PV/battery insulation monitoringIntegration
AC relay detectionIntegration

General
Max. efficiency99.5%
On/off grid switching time (ms)<20
Operating temperature range (℃)-30~+60(>45 derating)
Max. operating altitude (m)4000(>3000 derating)
CoolingAir cooling
Dimensions W*D*H (mm)800*900*19501200*900*1950
Weight (kg)450900