>Power Conversion System (1500V-String )

Please fill in the email and download the information immediately

It features PQ/VSG working modes with grid-forming function, small size and high power density, supports multi-module parallel connection for flexible configuration, adopts a modular design for precise battery management, and holds an IP66 protection rating with optional C4~C5 anti-corrosion grade for harsh environments.

Power Conversion System (1500V-String )
Power Conversion System (1500V-String )
Product Highlights
Safe and reliable
IP66 & optional C4~C5 anti-corrosion degree for harsh environment.
Flexible configuration
PQ, VSG working mode with grid-forming function;Small size & high power density.
Convenient operation and maintenance
Supports multi-module parallel connection for flexible configuration and features a modular design for precise battery management.
Choose our benefits

Save more installation, commissioning costs

Reduce the use of fossil fuels and be more environmentally friendly

Increase the penetration of renewable energy

Continuous and stable power supply

Avoid the upgrading of grid and achieve the expected effect quickly

Rated power (kW)145174200228186215250
DC data
DC voltage range (V)580~1,500696~1,500800~1,500914~1,5001,000~1,500
Max. DC current (A)281281281281209241281

AC data
Rated power (kW)145174200228186215250
Max. output power (kW)160191220251205237275
Reactive power range (kvar)0~1520~1830~2100~2400~1950~2260~262
Grid type3W+PE
Isolation methodNo isolation

Grid-connected operation data
Rated grid voltage (V)400480550630690
Permitted grid voltage (V)340~440408~528468~605536~693586.5~759
Rated grid frequency (Hz)50 / 60
Permitted grid frequency (Hz)45~55 / 55~65
Total harmonic distortion of current<3% (Rated power)
Power factor-1~1
Charge-discharge conversion time (ms)<20

Off-grid operation data
Rated output voltage (V)400480550630690
Voltage imbalance2%, not exceeding 4% for short periods
THDu<3%(No load or rated resistive load)
Dynamic voltage transient range<10% (under resistive load/balanced load conditions, when the load suddenly changes from 20% to 100% or from 100% to 20%)
Output overvoltage protection valueAdjustable
Output undervoltage protection valueAdjustable

General data
Applicable grounding systemIT
Max. efficiency99%
Allowable ambient temperature (℃)-40~+60 (Use with derating above 45)
Allowable relative humidity0~100%
Allowable altitude (m)<5,000 (A reduction of over 3,000)
Noise (dB)75
DI interfaceGroup 4
DO interfaceGroup 2
Corrosion resistance gradeC3 (C4 / C5 Optional)
Overvoltage protectionDC Type ІІ / AC Type ІІІ
Wiring methodBottom-in, bottom-out (Quick-connect terminals)
Protection gradeIP66
Cooling methodIntelligent Air Cooling
Indicator lightLED indicator
Communication interfaceEthernet, RS485, CAN, Near Field Debugging WiFi (Optional)
Communication protocolModbus TCP / RTU
Dimensions (W*H*D) (mm)795*915*294 (No hanging board)
Weight (kg)100 (net weight)
CertificationCGC, high/low voltage ride-through、IEC62477、IEC61000、EN50549